Control Chart
SPC control charts for process stability
Anatomy of a Control Chart
A control chart (SPC chart) plots a process metric over time together with statistical limits. It separates random variation (process "in control") from systematic deviations (special causes) — and is the standard Control-phase tool to keep an improved process in check long-term.
Center line (CL): The centre line CL is the mean of observed values or subgroup means. It represents the current process level.
UCL and LCL (±3σ): UCL and LCL are the upper and lower control limits, typically at 3 standard deviations from the mean. Deviations within are treated as random; points outside indicate a special cause.
Zones A, B, C: The region between center line and limits is divided into three zones of one standard deviation each. Western Electric and Nelson rules use these zones to detect non-random patterns.
Special cause: A special cause is an influence outside normal process variation — e.g. a tool break, a new operator, a material change. Must be identified and removed before the process continues.
Chart types: I-MR for individuals, X̄-R and X̄-S for subgroups, p and np for proportions (defective/not), c and u for counts (defects per unit). Choice depends on data type and subgroups.
Control charts prevent processes from drifting unnoticed. They are not quality verdicts but early-warning systems: they show something is happening before the spec is violated.
Approach
- Pick chart type by data type and subgroup structure.
- Collect enough baseline data — typically 20–25 subgroups or 100+ individuals.
- Compute center line and limits from the baseline (Phase I).
- Check for outliers and patterns — exclude special causes from Phase I and recompute limits.
- Start ongoing monitoring (Phase II) — each new point is checked against fixed limits.
- On a rule violation, find, document, and eliminate the cause.
- Recompute limits only when the process was demonstrably and intentionally changed.
Rules for Special Causes (Nelson)
- 1 point outside the 3σ limits — clearly out of control.
- 9 points in a row on the same side of the center line — level shift.
- 6 points rising or falling in a row — trend.
- 14 points alternating — systematic zig-zag.
- 2 of 3 points in zone A (>2σ) — near-limit excursion more often than expected.
- 4 of 5 points in zone B or beyond (>1σ) — process spreading wider than normal.
On the MR, R and S chart only rules 1–4 apply (as in Minitab). The dispersion statistic is skewed, so zones built from (UCL − center line)/3 would have no defined false-alarm rate there.
The rules are hints, not verdicts. Every violation should trigger a cause search, not an automatic alarm. Too many active rules create false alarms.
As in Minitab, only rule 1 is on by default. On 25 points of a stable process it falsely signals a special cause in about 7 % of cases, rules 1–6 together in about 24 %. Switch further rules on deliberately — while establishing limits, Minitab recommends rules 1, 2 and 7.
Pitfalls
Spec limits instead of control limits: USL/LSL come from the customer, UCL/LCL from process data. Mixing them (drawing spec limits on the chart and treating them as control limits) is among the most common SPC mistakes.
Wrong chart type: Applying an I-MR chart to proportion data or a p-chart to individual measurements yields nonsense limits. Data type and subgroup structure must fit the chart type.
Too few baseline data: With 5 subgroups the limits are unstable and keep shifting. At least 20–25 subgroups are needed for a reliable baseline.
Too many rules enabled: Every extra rule increases the false-alarm rate. Enabling all Nelson rules gives a "hit" every few points on average — and the team stops taking the chart seriously.
Recomputing limits after every change: Pulling limits along with every violation hides the drift. Only adjust limits when there is a documented reason (new process, new equipment).
Chart without reaction: A control chart without a defined reaction procedure is decoration. Per violation, it must be clear: who looks, who decides, who documents.
Stages — multiple baselines
When a process has been deliberately retuned (tool change, new batch, material switch, machine override), global limits produce a misleading picture — they mix the old and new variation. With stages each section gets its own center line and control limits.
Input: In the "Stage boundaries" field, enter the number of the last point of each stage, separated by commas. Example: "12, 25" with 30 points yields three stages: 1–12, 13–25, 26–30. For X̄-R and X̄-S the numbers count individual values; a boundary should be a multiple of the subgroup size, otherwise the split subgroup is counted in the earlier stage (the chart warns about this).
Effect: The chart shows stepped center line and limits with dashed vertical separators at each stage break. Each stage is judged by its own limits: the Nelson tests run per stage and runs (e.g. test 2) restart at every stage boundary, on both charts. The moving range across a stage boundary is not plotted. The KPIs and Cp/Cpk describe the last stage, i.e. the process as it runs now.
Stages do not replace the baseline count — they are a different mechanism. Either use a baseline count (classic Phase I/II) or stage boundaries (multiple stable sections). When set, stages override the baseline count.
Phase I / II and Annotations
The classic SPC workflow has two phases: Phase I collects baseline data, identifies special causes and excludes them until the baseline is "in control". Phase II locks those limits and checks new data points against them.
Annotations (Phase I): Click a violation row to open a dialog: record the cause as free text and optionally exclude the point from the limit computation. Excluded points appear as a gray ✕ — they stay on the chart but no longer influence UCL/LCL. Limits update live after each exclusion.
Phase II — Freeze limits: "Freeze limits" stores the current limits. Subsequent data points are checked against these fixed limits without UCL/LCL changing. "Thaw" returns to the live recompute mode. The limits belong to the column they were computed from — selecting a different column discards them.
Phase II is only available without stages — multi-stage charts already have per-stage limits; an additional freeze would be double bookkeeping.
References
- Melzer, Almut (2019)Six Sigma – kompakt und praxisnah: Prozessverbesserung effizient und erfolgreich implementieren2nd ed., Springer Gabler, Wiesbaden, ISBN 978-3-658-23754-7doi:10.1007/978-3-658-23755-4Cross-check of the special-cause tests: test 4 fires at 14 alternating points, MR, R and S charts evaluate tests 1–4 only. The book works with test 1 only, which is now also the default. Staged chart (ch. 5.2, p. 100, Fig. 5.4): each stage has its own limits and is judged against them.
- Montgomery, Douglas C. (2009)Introduction to Statistical Quality Control6th ed., John Wiley & Sons, Hoboken, NJ, ISBN 978-0-470-16992-6Sec. 5.3.6: every additional sensitizing rule raises the false-alarm rate; basis for the default of test 1 only.
Examples
This module ships with the following example datasets — load any of them in the app with a single click.
Available in the following cycles
- DMAIC: Control
- DMADV: Verify
- 8D: D6 — Implementation