MSA Type 2/3 (Gage R&R)

Measurement System Analysis Type 2 (with operator, Gage R&R) and Type 3 (no operator, automated measurement systems)

Overview

The MSA Type 2 study (Gage R&R, Repeatability & Reproducibility) decomposes measurement-system variation into three components: repeatability (same part, same operator), reproducibility (same part, different operators), and part-to-part variation. It is the standard check before process capability or control charts become trustworthy.

Repeatability (EV, Equipment Variation): Repeatability — variation when one operator measures the same part multiple times. It comes purely from the instrument and the measurement procedure — not from humans or parts.

Reproducibility (AV, Appraiser Variation): Reproducibility — variation when different operators measure the same part. Comes from handling, reading, fixturing. A high AV share indicates training needs or an unclear procedure.

Part-to-part (PV, Part Variation): Part-to-part variation between the selected parts themselves. Should dominate — if not, the system is mostly measuring itself, not the process.

GR&R in % (of variation or tolerance): Ratio of measurement-system variation (k·σ_GRR) to the study variation (%Study Var.) or to the tolerance T = USL − LSL (%Tolerance). The verdict rests on one of these two references, the verdict basis: < 10% is accepted, 10–30% conditionally accepted, 30% and above not accepted.

Number of Distinct Categories (ndc): ndc counts how many distinct levels the system can tell apart within the observed part range. Rule of thumb: ndc ≥ 5. Below 5 the process is seen too coarsely.

Gage R&R is a statistical experiment, not a number game. Part selection, order, operator blinding — all influence the result. A craftsmanlike setup matters more than the software.

Approach

  • Typical setup: 10 parts × 3 operators × 2–3 repeats = 60–90 measurements.
  • Pick parts spanning the process range — not all near the mean.
  • Use operators who run the process, not specially trained testers.
  • Randomize order, blind operators to which part is which.
  • Same procedure, same instrument, same fixture.
  • Analyze with the ANOVA method (not the range method for modern studies).
  • Assess GR&R percent, ndc, and component shares.
  • Factor k: 6 (99.73%) is the current standard (AIAG MSA 4th ed. 2010, Minitab, Bosch booklet 10 procedure 2). 5.15 (99%) is the AIAG 3rd ed. convention and remains selectable; studies saved earlier keep 5.15.
  • Verdict basis "Automatic": %Tolerance when LSL and USL are set (Bosch: reference quantity T, limits 10%/30%), otherwise %Study Var. Either reference can also be fixed.
  • Historical process σ (optional): adds the column %Process = σ/σ_hist·100. It is informational only, may exceed 100%, and changes neither the verdict nor ndc.
  • On failure, identify the cause (instrument, operator, fixture, procedure) and fix it.

Pitfalls

Parts too similar: If all 10 parts sit close together, the study fails from too little part variation — GR&R looks big because PV is small. Parts must span the relevant process range.

Operators know which part they have: Without blinding, they remember prior readings and "correct" unconsciously. Repeatability looks too good, real variation hides.

Order not randomized: Systematic order (e.g. operator 1 first, then operator 2) confounds drift with operator effect. Randomization is mandatory.

Only best operators tested: Pre-training the selected operators measures potential — not everyday reality. Results look great until real shifts run.

ndc ignored: GR&R 20% can come with ndc 3 — the system sees only three levels of the process. Read both indices together.

%Tolerance and %Study Var. disagree: The same study can be acceptable relative to the tolerance and not acceptable relative to the study variation — or the other way round. Choose the verdict basis by purpose: product acceptance against the specification → tolerance, process improvement → study variation.

Range method instead of ANOVA: The classic range method underestimates interactions. Modern studies use ANOVA — it reports repeatability, reproducibility, and the operator×part interaction separately.

Interpreting "10% is good": Whether 10% GR&R is enough depends on the use. For safety-critical tolerances even 10% may be too much; for rough manufacturing 20% is fine. Context beats table.

Type 2 vs. Type 3

Type 2 measures with operators (classic Gage R&R). Type 3 runs without operators — for automated measurement systems (CMM in automatic mode, in-process sensors, test rigs) where the operator has no influence on the reading.

When Type 3?: Whenever the operator is physically decoupled from the measurement: automated handling, fixed fixture, the part is placed and the machine measures on its own. No reading effect, no handling variation.

Leave the operator column empty: In the module, simply leave the operator column unset — the module detects Type 3 automatically and hides reproducibility (AV), the interaction section, and the by-operator charts. %GRR then equals the pure repeatability share (%EV).

Study plan (Bosch/VDA convention): Typical layouts: 25 parts × 2 replicates or 10 parts × 3 replicates. Without operators, more parts per study become realistic. With only 2 replicates the module shows a warning — more replicates improve the estimate of within-part variation.

Analysis: One-way random-effects ANOVA with parts as a random effect. σ²_GRR = σ²_Repeat, and the ndc plus %GRR thresholds (< 10 % / 10–30 % / > 30 %) remain identical to Type 2. Reproducibility is zero by definition.

References

  1. AIAG (2010)Measurement Systems Analysis (MSA) Reference Manual4th ed., Automotive Industry Action Group, Southfield, MI, ISBN 978-1-60534-211-5Basis for %GRR with 6·σ, ndc and the 10 % / 30 % acceptance limits.
  2. Melzer, Almut (2019)Six Sigma – kompakt und praxisnah: Prozessverbesserung effizient und erfolgreich implementieren2nd ed., Springer Gabler, Wiesbaden, ISBN 978-3-658-23754-7doi:10.1007/978-3-658-23755-4Cross-check of the type 2 study: multiplier 6 instead of 5.15, verdict optionally via %tolerance, optional historical process σ.

Examples

This module ships with the following example datasets — load any of them in the app with a single click.

Available in the following cycles

  • DMAIC: Measure
  • DMADV: Measure
  • 8D: D2 — Describe the Problem